Vortex Flow Meter VFM60MV flanged 150C

Vortex Flow Meter VFM60MV flanged 150C is a flanged vortex flow meter for measuring steam, gas and liquid flow. It is rated for temperatures up to 150°C. Its digital display shows flow rate, total flow, temperature and pressure.

Vortex Flow Meter VFM60MV flanged vortex flow meter

The flanged VFM60MV is suitable for steam, gas and liquid flow measurement in industrial applications. The digital display gives a clear reading of flow rate, total flow, temperature and pressure in one place.

How a Vortex Flow Meter Measures Flow

A Vortex Flow Meter measures flow with a bluff body, sometimes called a shedder bar, placed in the path of the fluid. As steam, gas or liquid passes the body, it sheds alternating vortices, or swirling eddies, first from one side and then from the other. This repeating pattern is known as a von Kármán vortex street.

A sensor in the meter detects the pressure pulses created by those vortices. The faster the fluid moves, the more often vortices are shed, so the pulse frequency rises with flow velocity. The meter converts that frequency into a flow rate, so the reading follows the movement of the fluid rather than the turning of a spinning part.

Because there is no rotor in the flow path to wear, this type of meter is often chosen where a simple and robust measurement is wanted. The same basic principle applies to steam, gas and liquid, although the way the reading is used can differ from one fluid to another.

Vortex Flow Meter Uses for Steam, Gas and Liquid

Steam is one of the most common uses for a vortex flow meter. In a boiler house or a heating system, the meter can track how much steam is being used, which helps operators see where steam goes and whether use changes over time. That kind of record supports day-to-day running and longer-term planning.

The same meter principle also suits gas and liquid. Gas lines in industrial plants and liquid lines carrying water or other process liquids can both be measured in the same way, by the vortices the flow creates. Using one type of meter for different fluids can make selection, fitting and reading easier for the people who look after the plant.

A vortex flow meter is therefore a practical choice where steam, gas and liquid may all need to be measured in different parts of a site. The VFM60MV on this page is the flanged model for those duties, with the digital display described above.

The Flanged Connection on This Vortex Flow Meter

The VFM60MV is a flanged vortex flow meter, which means it is made to bolt into a pipe run between matching flanges. A gasket between the faces helps form a sealed joint, and the bolted connection holds the meter firmly in place in fixed industrial pipework.

A flanged connection also makes the meter easier to remove for inspection or replacement than a meter that is built into a length of pipe. The meter can be unbolted, checked and refitted, or swapped for another unit, without cutting the pipe. That is useful in plants where flow measurement must be kept working with as little disruption as possible.

Reading the Digital Display on a Vortex Flow Meter

The digital display on the VFM60MV shows four readings in one place: flow rate, total flow, temperature and pressure. Flow rate shows how fast the fluid is moving through the meter at the time of the reading, while total flow adds up how much has passed through over time.

Temperature and pressure are shown beside the flow readings because both affect how steam and gas behave in a pipe. Seeing all four values together helps an operator check the flow in context, rather than looking at a flow reading on its own. The display is shown in the picture above, so you can see the layout before the meter is fitted.

Choosing the Right Vortex Flow Meter

Choosing the right Vortex Flow Meter starts with the fluid. Confirm whether the line carries steam, gas or liquid, and confirm that the temperature stays within the rating for the model you choose. The VFM60MV on this page is rated for temperatures up to 150°C, so the process temperature should stay within that limit.

Next, check the connection and the readings you need. The flanged connection must match the flanges on the pipe run, and the meter should show the readings the job calls for. For the VFM60MV, those readings are flow rate, total flow, temperature and pressure, all on the digital display.

If the meter is for a boiler system, it may help to look at the other parts that keep that system running. KBS Industries also supplies Boiler Spare Parts for Cleaver-Brooks boilers, and the team can help you find the right part for your boiler. For a general explanation of the vortex-shedding principle, see the Wikipedia article on the vortex flowmeter.