Tuesday, November 17, 2026

Vortex Flow Meter VFM80 – Gas, Steam and Liquid

The Vortex Flow Meter VFM80 is a vortex meter for gas, steam and liquid, built for high-velocity lines. It covers all three media in one instrument, and shares its accuracy, power, ambient limits, protection and materials with the VFM60. It differs in outputs and velocity range, making it the choice for high-velocity gas and steam duty.

Vortex Flow Meter VFM80

It works on the vortex shedding principle: a bluff body sheds vortices alternately from each side, and the shedding rate rises with flow velocity. The meter counts that rate, with no moving parts in the stream to wear – well suited to steam and gas lines where flow swings widely.

The VFM80 meters gas, steam and liquid – it is not gas-only. Respect the size, velocity, temperature and pressure limits below. For very small gas-only lines, see the micro meters at the end of this page.

Features

  • One meter for gas, steam and liquid – not gas-only; a single meter type for all three media.
  • Built for high-velocity lines – gas and steam reach up to 120 m/s in expanded form on larger sizes.
  • Widest gas and steam velocity range in this range – standard up to 60 or 70 m/s, expanded up to 120 m/s.
  • Pulse and 3 x 4-20 mA outputs, with RS485 and Bluetooth.
  • Readings shown on the meter display at the line.
  • No moving parts in the stream to wear; well suited to steam and gas lines where flow swings widely.
  • Shares accuracy, power, ambient limits, protection and materials with the VFM60.
  • 16 to 32 V DC power, -20 to 60 °C ambient, IP65/IP67 protection.

Specification

Measurement range

The velocity range is where the VFM80 stands apart. Gas and steam reach up to 120 m/s in expanded form on larger sizes; the standard range is up to 60 or 70 m/s. Liquid covers 0.3 to 6 m/s.

SizeGas and steam, standardGas and steam, expanded
DN15 to DN206 to 60 m/s6 to 60 m/s
DN254 to 60 m/s4 to 60 m/s
DN324 to 70 m/s4 to 80 m/s
DN40 to DN3002 to 70 m/s2 to 120 m/s
Liquid, all sizes0.3 to 6 m/s0.3 to 6 m/s

Specification of VFM80 vortex flow meter

ItemVFM80 detail
Process connectionFlange or wafer, DN15 to DN300
Body stylesWafer and flanged
Nominal sizesDN15 to DN300, both styles
Flange standardsDIN PN16, PN25, PN40, PN63; JIS 10K, 20K, 30K; ANSI Class 150, 300, 400
Extended ratingsMode codes to Class 900 and 150 barg
Medium temperatureStandard -40 to 150 °C; medium -40 to 250 °C; high -40 to 350 °C
Fluid pressureUp to 16 Bar wafer; 16, 25, 40 or 63 Bar flanged
Flow accuracy±1.0% of reading
Pressure accuracy±0.5% of full scale
Temperature accuracy±1.0 °C, or ±1% of full scale above 100 °C
OutputsPulse and 3 x 4-20 mA; RS485 and Bluetooth
Power supply16 to 32 V DC
Ambient temperature-20 to 60 °C
ProtectionIP65 and IP67

The VFM80 is a natural choice for steam mass flow, where compensated mass measurement is needed. It also fits gas and liquid lines in refineries, petrochemical and chemical plants, and in food and pharmaceutical plants where hygiene matters.

Model selection

SelectionVFM80 options
Body styleWafer or flanged
Nominal sizeDN15 to DN300
Flange standardDIN PN16, PN25, PN40, PN63; JIS 10K, 20K, 30K; ANSI Class 150, 300, 400
Extended ratingMode codes to Class 900 and 150 barg
Fluid temperatureStandard -40 to 150 °C; medium -40 to 250 °C; high -40 to 350 °C
OutputsPulse and 3 x 4-20 mA; RS485 and Bluetooth
Velocity rangeStandard up to 60 or 70 m/s (gas and steam); expanded up to 120 m/s; liquid 0.3 to 6 m/s

Dimensions: DN sizes and face-to-face length L

The VFM80 is made from DN15 to DN300 (1/2 to 12 inches); the face-to-face length L below is for Class 150 and Class 300 flanged models.

DN sizeSize (inches)L Class 150 (mm)L Class 150 (inches)L Class 300 (mm)L Class 300 (inches)
DN151/21867.321867.32
DN203/41867.321867.32
DN2511867.321867.32
DN321-1/41867.321867.32
DN401-1/21867.322068.11
DN5021867.322068.11
DN652-1/22068.112268.90
DN8032068.112268.90
DN10042068.112268.90
DN12552268.9025610.08
DN15062268.9025610.08
DN20082268.9025610.08
DN2501025610.0830612.05
DN3001230612.0535614.02

When choosing between this model and the others in the range, the deciding points are usually the media, the size and the top velocity. The VFM80 covers gas, steam and liquid from DN15 to DN300, with the widest gas and steam velocity range in this range. For the same media in a standard velocity range, see the Vortex Flow Meter VFM60. For small gas-only lines, see the Vortex Flow Meter VFM55MV Micro and the Vortex Flow Meter VFM52MV Micro. The vortex flow meter hub page covers the VFM60MV flanged 150C model in detail.

Document

If you are unsure which size, temperature version or velocity range fits your line, check the figures above first.