Thermal Flow Meter TGF260 Micro – Gas
TGF260 Micro Thermal is a small thermal mass flow meter for gas in DN15, DN20 and DN25 lines, that is half inch, three quarter inch and one inch pipe. It measures mass flow directly from the heat taken away by the moving gas, so it reports flow in normal litres per minute without a separate pressure or temperature correction in normal use. It is the smallest model in the thermal range, and it is aimed at small gas lines where a full size insertion or flanged meter would be far too large, too costly and too hard to fit.

TGF260 Micro Thermal starts to measure at 0.3 Nm/s and reaches 90 Nm/s in its widest band — a narrower top end than the larger models’ 180 or 240 Nm/s, matching its small DN15 to DN25 flows. A 2 inch LCD display shows the reading at the meter, and readings can be recorded and exported through a phone app. A self-check flags a fault instead of letting a bad reading pass.
What sets the TGF260 Micro Thermal apart is its response time: 100 milliseconds, against 1 second for the larger thermal models. That suits a small line whose flow changes quickly, for example a line feeding a machine that starts and stops, where a slow meter would miss the peak.
Features
- Smallest model in the thermal range – for gas in DN15, DN20 and DN25 lines (1/2, 3/4 and 1 in).
- Direct mass flow measurement – reports flow in normal litres per minute (Nl/min) without a separate pressure or temperature correction in normal use.
- Fastest response in the thermal range – 100 milliseconds, against 1 second for the larger thermal models; suits a line whose flow changes quickly.
- Wide velocity range, 0.3 to 90 Nm/s, in three bands; the standard band is 0.6 to 60 Nm/s.
- Compact threaded body – G thread, male, in DN15, DN20 and DN25; fits in 130 to 160 mm of pipe.
- 2 inch LCD display at the meter; readings recorded and exported through a phone app.
- Self-check flags a fault instead of letting a bad reading pass.
- Frequency, 4 to 20 mA, RS485 and Bluetooth outputs.
- PC and ABS plastic enclosure, IP65; for indoor use.
The TGF260 Micro Thermal works on the same thermal mass principle as the larger thermal models: two sensing elements sit in the gas stream, one heated and one measuring gas temperature. Extra power holds the heated element at its set temperature, and that power rises with mass flow.
The result is a direct mass flow reading in normal litres per minute, at 20 °C and 101.325 kPa.
Three velocity bands are listed; the band is chosen when the meter is ordered. The bands are 0.3 to 30, 0.6 to 60 and 0.9 to 90 Nm/s, with 0.6 to 60 Nm/s as the standard band. A low band suits a line that runs gently; a high band suits a line that can surge.
The TGF260 Micro Thermal fits small gas lines in factories, workshops, laboratories and pilot plants, where a small, low-cost meter is needed for a DN15 to DN25 line. Because it is so small, it is also a practical choice where space is tight.
The meter is built for indoor plant conditions. Its enclosure is PC and ABS plastic, its display cover is PA with 15 percent glass fibre, and its ambient range is minus 20 to 60 °C.
Specification
Measurement range
The table below gives the flow range for each pipe size and for each of the three velocity bands, in normal litres per minute.
| PIPE SIZE | 0.3 TO 30 NM/S, NL/MIN | 0.6 TO 60 NM/S, NL/MIN | 0.9 TO 90 NM/S, NL/MIN |
|---|---|---|---|
| DN15 (1/2 in) | 3.2 to 318 | 6.4 to 636 | 9.5 to 953 |
| DN20 (3/4 in) | 5.6 to 565 | 11.3 to 1,130 | 16.9 to 1,695 |
| DN25 (1 in) | 8.8 to 883 | 17.7 to 1,766 | 26.5 to 2,648 |
To put those figures in cubic metres per hour: 953 Nl/min is about 57 Nm3/h, 1,695 Nl/min is about 102 Nm3/h, and 2,648 Nl/min is about 159 Nm3/h.
Specification of TGF260 Micro Thermal flow meter
| Item | TGF260 Micro Thermal |
|---|---|
| Fluid | Gas |
| Display | LCD |
| Pipe size | DN15 (1/2 in), DN20 (3/4 in), DN25 (1 in) |
| Process connection | G thread, male |
| Velocity range | 0.3 to 90 Nm/s, in three bands; 0.6 to 60 Nm/s is the standard band |
| Pressure | 16 bar (232 psi) |
| Fluid temperature | Minus 40 to 85 °C (minus 40 to 185 °F) |
| Accuracy | 1.5 percent of reading plus 0.5 percent of full scale |
| Repeatability | One third of the accuracy figure |
| Response time | 100 milliseconds |
| Power supply | 16 to 32 V DC |
| Outputs | Frequency, 4 to 20 mA, RS485 and Bluetooth |
| Ambient temperature | Minus 20 to 60 °C |
| Protection | IP65 |
| Materials | Sensor alumina ceramic; bore aluminium; enclosure PC plus ABS; display cover PA plus 15 percent glass fibre |
Accuracy is 1.5 percent of reading plus 0.5 percent of full scale — best at high flow, less good at low flow.
Dimensions
The catalog gives only two dimensions for the TGF260 Micro Thermal: the body length and the thread size. Body length is the length of pipe the meter will take up.
| PIPE SIZE | BODY LENGTH | THREAD |
|---|---|---|
| DN15 (1/2 in) | 130 mm (5.12 in) | G 1/2 in |
| DN20 (3/4 in) | 160 mm (6.30 in) | G 3/4 in |
| DN25 (1 in) | 160 mm (6.30 in) | G 1 in |
When fitting the meter, the body length is the length of pipe the meter will take up, and the thread size must match the pipe fitting.
Model selection
When ordering, give the velocity band, the output set and the pipe size. The table below lists the choices for each item.
| Selection | Options |
|---|---|
| General model | TGF260 Micro Thermal – Standard |
| Measurement velocity | 1 – 0.3 to 30 Nm/s (option); 2 – 0.6 to 60 Nm/s (standard); 3 – 0.9 to 90 Nm/s (option) |
| Transmitter output | A – Frequency, 4 to 20 mA, RS485 and Bluetooth (standard output set) |
| Pipe size | 15 – DN15 (1/2 in); 20 – DN20 (3/4 in); 25 – DN25 (1 in) |
| Process connection | G thread, male |
| Power supply | 16 to 32 V DC |
| Fluid | Gas |
The standard ordering code is TGF260-2-A, followed by the pipe size, where 2 is the standard 0.6 to 60 Nm/s band, 1 is the optional 0.3 to 30 Nm/s band and 3 is the optional 0.9 to 90 Nm/s band, and A is the standard output set of frequency, 4 to 20 mA, RS485 and Bluetooth. The pipe size is given as 15 for DN15, 20 for DN20 and 25 for DN25.
Confirm the full ordering code against the COMATE 2026-2027 catalog, thermal mass flow meter chapter, pages 42 to 43, before ordering.
Document
The meter is described in the COMATE 2026-2027 catalog, thermal mass flow meter chapter, pages 42 to 43, where the full measuring range, dimension and ordering code tables are printed. This page gives the main figures from that chapter in summary form. Compared with the TGF680, TGF460 and TGF410, it is the only model for pipes as small as DN15, the only one with a 100 millisecond response, and the only one that fits in 130 to 160 millimetres of pipe.
Related flow meters
- Thermal Flow Meter TGF680 – the larger thermal model for gas and steam, up to 240 Nm/s and 450 °C.
- Thermal Flow Meter TGF460 – the economical thermal model for air, nitrogen, oxygen and carbon dioxide, up to 180 Nm/s.
- Thermal Flow Meter TGF410 – the economical thermal model for air and nitrogen, up to 180 Nm/s, for indoor use.
- Flow Meter – the Flow Meter hub page, with the vortex flow meter range.
- Vortex Flow Meter VFM60 – a vortex meter for gas, steam and liquid in the same Flow Meter range.