Thermal Flow Meter TGF680 – Gas and Steam
TGF680 is a thermal mass flow meter made for gas and steam lines, including compressed air, nitrogen, oxygen and other industrial gases. It measures mass flow directly from the cooling effect of the moving gas on a heated sensor, so it reports flow in normal cubic metres per hour without a separate pressure or temperature correction. It suits plants that need one instrument to cover a wide range of pipe sizes, from DN25 to DN2500, and is available as an insertion probe, a wafer unit or a flanged unit.

TGF680 works on the thermal mass principle: two sensing elements sit in the gas stream, one heated and one measuring gas temperature. Extra power holds the heated element at its set temperature, and that power rises with mass flow. The meter turns that power into direct mass flow in normal cubic metres per hour, at 20 °C and one atmosphere.
TGF680 is aimed at users who need a dependable reading at both low and high flow. It starts to measure at 0.3 Nm/s and stays dependable up to 240 Nm/s. A 2 inch TFT display can rotate 180 degrees, and readings can be recorded and exported through a phone app. It responds in about 1 second, and a self-check flags a sensor fault for maintenance.
Features
- Direct mass flow measurement – reports flow in Nm3/h without a separate pressure or temperature correction.
- Wide velocity range, 0.3 to 240 Nm/s, in seven bands; the default band is 0.9 to 90 Nm/s.
- One instrument covers DN25 to DN2500 – available as an insertion probe, a wafer unit or a flanged unit.
- Multi-gas set-up: a compensation factor for different gas types is stored in the meter, so one meter can serve more than one gas.
- Multi-variable version brings flow, temperature and pressure together in one instrument, cutting transmitters and cabling.
- 2 inch TFT colour display that rotates 180 degrees; readings can be recorded and exported through a phone app.
- Fast response, about 1 second, with a self-check that flags a sensor fault for maintenance.
- Built for plant conditions: IP65 and IP67 enclosure, ambient -20 to 60 °C, with an explosion-proof version available.
- Insertion probe installs without cutting the pipe and can be removed for cleaning without taking the line out of service.
Specification
Measurement range
Velocity bands are chosen when the meter is ordered; the default is 0.9 to 90 Nm/s. A low band, 0.3 to 30 Nm/s, suits gentle flows, and a 240 Nm/s band suits lines with short surges or peaks.
The table below gives the normal volume flow range for the default 0.9 to 90 Nm/s band, at 20 °C and 1 atmosphere.
| Pipe size | Minimum flow, Nm3/h | Maximum flow, Nm3/h |
|---|---|---|
| DN25 (1 in) | 1.59 | 158.9 |
| DN32 (1.25 in) | 2.60 | 260.3 |
| DN40 (1.5 in) | 4.07 | 406.8 |
| DN50 (2 in) | 6.36 | 635.6 |
| DN65 (2.5 in) | 10.74 | 1,074.2 |
| DN80 (3 in) | 16.27 | 1,627.1 |
| DN100 (4 in) | 25.42 | 2,542.4 |
| DN125 (5 in) | 39.72 | 3,972.5 |
| DN150 (6 in) | 57.20 | 5,720.3 |
| DN200 (8 in) | 101.69 | 10,169.5 |
| DN250 (10 in) | 158.9 | 15,889.8 |
| DN300 (12 in) | 228.81 | 22,881.4 |
For other velocity bands, flow scales with velocity: the lowest band, 0.3 to 30 Nm/s, gives one third of the flow in the table, and the highest band, 2.4 to 240 Nm/s, gives eight thirds of it. The table above is only the default band.
Specification of TGF680 thermal mass flow meter
| Item | TGF680 detail |
|---|---|
| Fluid | Gas and steam |
| Display | 2 inch TFT colour display, can rotate 180 degrees |
| Pipe size, insertion | DN25 to DN2500 (1 in to 100 in) |
| Pipe size, wafer | DN25 to DN300 (1 in to 12 in) |
| Pipe size, flanged | DN25 to DN500 (1 in to 20 in) |
| Velocity range | 0.3 to 240 Nm/s, in seven bands; 0.9 to 90 Nm/s is the default |
| Pressure, insertion | 16 bar |
| Pressure, wafer | 16, 25, 40 or 63 bar |
| Pressure, flanged | DIN PN16, PN25, PN40 or PN63; JIS 10K, 20K or 30K; ANSI Class 150, 300 or 400 |
| Outputs | Pulse, three 4 to 20 mA, RS485 and Bluetooth; or RS485, one HART over 4 to 20 mA plus two 4 to 20 mA, Bluetooth |
| Fluid temperature | -40 to 150 °C (302 °F), -40 to 250 °C (482 °F), or -40 to 450 °C (842 °F) |
| Accuracy | 1.5% of reading plus 0.5% of full scale |
| Repeatability | One third of the accuracy figure |
| Response time | 1 second |
| Power supply | 16 to 32 V DC |
| Ambient temperature | -20 to 60 °C |
| Protection | IP65 and IP67 |
| Explosion proof | Ex db IIC T6 Ga; CSA Class I Division 1, Groups B, C, D, T1 to T6, Type 4X |
| Materials | Sensor 316L; probe 304, 316L optional; bore 304, 316L optional; enclosure aluminium; other materials on request |
Accuracy is 1.5 percent of reading plus 0.5 percent of full scale – best at high flow, less good at very low flow. Repeatability is one third of the accuracy figure.
TGF680 fits gas and steam systems in factories, utilities and process plants. It suits compressed air and nitrogen metering, giving a mass reading without separate pressure or temperature correction, and steam lines up to 450 °C. Because it measures mass flow directly, the reading stays meaningful when line pressure or temperature changes.
The insertion form is the most flexible, fitting pipes from DN25 to DN2500 (1 to 100 inches). The probe goes into the line through a fitting, so it can be installed without cutting the pipe and removed for cleaning without taking the line out of service. The wafer form fits DN25 to DN300, and the flanged form DN25 to DN500.
Model selection
| Ordering item | TGF680 options |
|---|---|
| Fluid | Gas or steam (compressed air, nitrogen, oxygen and other industrial gases) |
| Velocity band | Seven bands, 0.3 to 240 Nm/s; default 0.9 to 90 Nm/s |
| Process connection | Insertion probe, wafer unit, or flanged unit |
| Wetted materials | Sensor 316L; probe 304 (316L optional); bore 304 (316L optional); other materials on request |
| Transmitter | Integral or remote |
| Output set | Pulse, three 4 to 20 mA, RS485 and Bluetooth; or RS485, one HART over 4 to 20 mA plus two 4 to 20 mA, Bluetooth |
| Power supply | 16 to 32 V DC (ordering code: 13.5 to 42 V DC; 85 to 265 V AC converter optional) |
| Pipe size | Given in mm as a four-digit figure, e.g. 0050 for DN50 |
A standard ordering code starts TGF680-1-2-12-1-N-T-M-N-1-1, followed by the pipe size in mm as a four-digit figure, e.g. 0050 for DN50. When ordering, give the fluid, velocity band, process connection, wetted materials, whether the transmitter is integral or remote, cable entry, output set, power supply and pipe size. Note: the ordering table lists power as 13.5 to 42 V DC (85 to 265 V AC converter optional), while the specification table gives 16 to 32 V DC – confirm the supply against the form ordered.
Dimensions
For the insertion form, probe length sets how far into the pipe the sensor reaches; overall length is probe length plus the head. For the flanged form, bore length is the face-to-face length, and height is measured from the pipe centreline to the top of the display head.
Insertion probe
| Insertion probe length | Overall length | Pipe size |
|---|---|---|
| 290 mm (11.42 in) | 432 mm (17.01 in) | DN40 to DN200 (1.5 in to 8 in) |
| 440 mm (17.32 in) | 582 mm (22.91 in) | DN40 to DN500 (1.5 in to 20 in) |
| 690 mm (27.17 in) | 832 mm (32.76 in) | DN40 to DN1000 (1.5 in to 40 in) |
| 1000 mm (39.37 in) | 1142 mm (44.96 in) | DN40 to DN1500 (1.5 in to 60 in) |
| 1500 mm (59.06 in) | 1642 mm (64.65 in) | DN40 to DN2500 (1.5 in to 100 in) |
Flanged, DIN PN16
| Flanged, DIN PN16 | Bore length | Height |
|---|---|---|
| DN25 (1 in) | 165 mm (6.50 in) | 270 mm (10.63 in) |
| DN50 (2 in) | 175 mm (6.89 in) | 270 mm (10.63 in) |
| DN100 (4 in) | 209 mm (8.23 in) | 320 mm (12.60 in) |
| DN150 (6 in) | 255 mm (10.04 in) | 410 mm (16.14 in) |
| DN200 (8 in) | 269 mm (10.59 in) | 410 mm (16.14 in) |
| DN300 (12 in) | 341 mm (13.43 in) | 410 mm (16.14 in) |
For a large pipe, the insertion probe is the practical choice, fitting up to DN2500 without a large flanged spool. The wafer form suits a smaller pipe where a compact meter between flanges is wanted, and the flanged form suits a pipe where a bolted joint at each end is preferred.
Also in this range: the Thermal Flow Meter TGF460, an economical thermal model for air, nitrogen, oxygen and carbon dioxide, up to 180 Nm/s; the Thermal Flow Meter TGF410, an economical thermal model for air and nitrogen, for indoor use; the Thermal Flow Meter TGF260 Micro, a small threaded thermal meter for DN15 to DN25 gas lines; and the vortex range on the flow meter hub page, including the Vortex Flow Meter VFM60 for gas, steam and liquid.
Document
The meter is described in the COMATE 2026-2027 catalog, thermal mass flow meter chapter, pages 29 to 33, where the full measuring range, dimension and ordering code tables are printed. This page gives the main figures from that chapter in summary form.
If you are unsure which form, velocity band or size fits your line, check the figures above first.