Thermal Flow Meter TGF460 – Air, Nitrogen, Oxygen and Carbon Dioxide
TGF460 is a thermal mass flow meter for air, nitrogen, oxygen and carbon dioxide, built as the economical model in the thermal range. It measures mass flow directly from the heat taken away by the moving gas, so it reports flow in normal cubic metres per hour without a separate pressure or temperature correction in normal use. It is aimed at plants that need a reliable gas flow reading for compressed air, nitrogen supply, oxygen supply and carbon dioxide, without paying for the wider temperature range, the steam service and the extra output channels of the larger TGF680.

TGF460 works on the thermal mass principle: two sensing elements sit in the gas stream, one heated and one measuring gas temperature. Extra power holds the heated element at its set temperature, and that power rises with mass flow. The meter turns that power into direct mass flow in normal cubic metres per hour, at 20 °C and one atmosphere.
TGF460 starts to measure at 0.3 Nm/s and reaches 180 Nm/s in its widest band, covering most industrial gas lines. A 2 inch TFT colour display can turn through 180 degrees, and readings can be recorded and exported through a phone app. It responds in about 1 second, and a self-check flags a fault instead of letting a bad reading pass.
Features
- Direct mass flow measurement – reports flow in Nm3/h without a separate pressure or temperature correction in normal use.
- Low-cost economical model – the most cost-effective solution in the thermal range.
- Wide velocity range, 0.3 to 180 Nm/s, in six bands; the default band is 0.9 to 90 Nm/s; 100:1 turndown ratio.
- No pressure loss, suitable for pipe in any shape with known sectional area.
- Compact, non-invasive design – smaller enclosure and thinner insertion probe; installs or removes without halting the fluid flow, and supports hot tapping on a live line.
- 2 inch TFT colour display that turns through 180 degrees; readings recorded and exported through a phone app.
- Fast response, about 1 second, with self-diagnosis that flags a fault instead of letting a bad reading pass.
- Optional pressure transmitter can be added alongside, for a pressure reading at the same point as the flow reading.
Specification
Measurement range
Six velocity bands are listed; the band is chosen when the meter is ordered. The bands are 0.3 to 30, 0.6 to 60, 0.9 to 90, 1.2 to 120, 1.5 to 150 and 1.8 to 180 Nm/s, with 0.9 to 90 Nm/s as the usual default. A low band suits a line that runs gently; a high band suits a line that can surge.
The table below gives the normal volume flow range for the default 0.9 to 90 Nm/s band, at 20 °C and 1 atmosphere, for DN25 to DN300.
| Pipe size | Minimum flow, Nm3/h | Maximum flow, Nm3/h |
|---|---|---|
| DN25 (1 in) | 1.59 | 158.9 |
| DN32 (1.25 in) | 2.60 | 260.3 |
| DN40 (1.5 in) | 4.07 | 406.8 |
| DN50 (2 in) | 6.36 | 635.6 |
| DN65 (2.5 in) | 10.74 | 1,074.2 |
| DN80 (3 in) | 16.27 | 1,627.1 |
| DN100 (4 in) | 25.42 | 2,542.4 |
| DN125 (5 in) | 39.72 | 3,972.5 |
| DN150 (6 in) | 57.20 | 5,720.3 |
| DN200 (8 in) | 101.69 | 10,169.5 |
| DN250 (10 in) | 158.9 | 15,889.8 |
| DN300 (12 in) | 228.81 | 22,881.4 |
For other velocity bands, flow scales with velocity: the lowest band, 0.3 to 30 Nm/s, gives one third of the flow in the table, and the widest band, 1.8 to 180 Nm/s, doubles the table values. Pick the band from the lowest flow the line will see, not only from its peak.
Specification of TGF460 thermal mass flow meter
| Item | TGF460 detail |
|---|---|
| Fluid | Air, nitrogen, oxygen and carbon dioxide |
| Display | 2 inch TFT colour display, can rotate 180 degrees |
| Pipe size, insertion | DN25 to DN600 (1 in to 24 in) |
| Pipe size, wafer | DN25 to DN200 (1 in to 8 in) |
| Pipe size, flanged | DN25 to DN500 (1 in to 20 in) |
| Pipe size, threaded | DN25 to DN50 (1 in to 2 in) |
| Velocity range | 0.3 to 180 Nm/s, in six bands; 0.9 to 90 Nm/s is the default |
| Turndown ratio | 100:1 |
| Pressure, insertion and threaded | 16 bar (232 psi) |
| Pressure, wafer | 16, 25 or 40 bar |
| Pressure, flanged | DIN PN16, JIS 10K or ANSI Class 150 |
| Outputs | Pulse, 4 to 20 mA, RS485, HART over 4 to 20 mA and Bluetooth |
| Communication | 4 to 20 mA with HART (optional); RS485 and Bluetooth (standard) |
| Data displayed | Mass flow, total flow, volume flow in normal condition |
| Fluid temperature | -40 to 150 °C (302 °F) |
| Accuracy | 1.5% of reading plus 0.5% of full scale |
| Repeatability | One third of the accuracy figure |
| Response time | 1 second |
| Power supply | 16 to 32 V DC (AC 85 to 264 V or DC 16 to 32 V) |
| Ambient temperature | -20 to 60 °C |
| Protection | IP65 and IP67 |
| Materials | Sensor 316L; probe 304, 316L optional; bore 304, 316L optional; enclosure aluminium |
Accuracy is 1.5 percent of reading plus 0.5 percent of full scale – best at high flow, less good at very low flow. Repeatability is one third of the accuracy figure.
TGF460 fits gas systems in factories, workshops and process plants. It suits compressed air networks, showing how much air each area uses and where air is being lost, and nitrogen and oxygen supply lines, where a steady mass flow reading is needed for control and accounting. It also suits carbon dioxide lines, for example in food and drink plants and welding gas supply. Fluid temperature is -40 to 150 °C, so it covers cold gas and warm compressed air, but it is not a steam meter – steam service belongs to the larger TGF680.
The insertion form is the most flexible, fitting pipes from DN25 to DN600 (1 to 24 inches). It also supports hot tapping, so it can be fitted to a live line through a tapping valve without shutting the line down, following the site’s hot tapping procedure. The wafer form covers DN25 to DN200, the flanged form DN25 to DN500, and the threaded form DN25 to DN50 for small lines.
Model selection
| Selection | Code | Description |
|---|---|---|
| General model | TGF460 | Standard |
| Measurement velocity | 1 | 0.3 to 30 Nm/s (option) |
| Measurement velocity | 2 | 0.6 to 60 Nm/s (standard) |
| Measurement velocity | 3 | 0.9 to 90 Nm/s (option) |
| Measurement velocity | 4 | 1.2 to 120 Nm/s (option) |
| Measurement velocity | 5 | 1.5 to 150 Nm/s (option) |
| Measurement velocity | 6 | 1.8 to 180 Nm/s (option) |
| Process connection | I1 | Insertion type with 255 mm probe (option) |
| Process connection | I2 | Insertion type with 320 mm probe (standard) |
| Process connection | I3 | Insertion type with 395 mm probe (option) |
| Process connection | F1 | Flanged insertion type up to 25 barG (362 psiG) (option) |
| Process connection | D1 | Flanged DIN PN16 up to 16 barG (232 psiG), DN15 to DN300 (option) |
| Process connection | D2 | Flanged DIN PN25 up to 25 barG (362 psiG), DN15 to DN300 (option) |
| Process connection | D3 | Flanged DIN PN40 up to 40 barG (580 psiG), DN15 to DN300 (option) |
| Process connection | C1 | Flanged ANSI CL150 up to 16 barG (232 psiG), 0.5 inch to 12 inch (option) |
| Process connection | C2 | Flanged ANSI CL300 up to 40 barG (580 psiG), 0.5 inch to 12 inch (option) |
| Process connection | J1 | JIS 10K up to 16 barG (232 psiG), DN15 to DN300 (option) |
| Process connection | J2 | JIS 20K up to 40 barG (580 psiG), DN15 to DN300 (option) |
| Wet part material | 1 | 316 stainless steel sensor with 304 stainless steel wet parts (standard) |
| Wet part material | 2 | 316 stainless steel sensor with 316 stainless steel wet parts (option) |
| Transmitter | T | Integral (standard) |
| Transmitter | R | Remote (option) |
| Cable gland | M | M20 x 1.5 (standard) |
| Cable gland | N | NPT 1/2 (option) |
| Transmitter output | 1 | Pulse/frequency + 4 to 20 mA + RS485 + Bluetooth (option) |
| Transmitter output | 2 | Pulse/frequency + 4 to 20 mA with HART + Bluetooth (standard) |
| Power supply | 1 | 13.5 to 42 V DC (standard) |
| Power supply | 2 | 13.5 to 42 V DC with 85 to 265 V AC, 50/60 Hz power converter (option) |
| Pipe size | xxxx | Four-digit pipe size, e.g. DN50 = 0050, DN300 = 0300 |
A standard ordering code starts TGF460-1-2-I2-1-N-T-M-N-1-1, followed by the pipe size in millimetres as a four-digit figure, for example 0050 for DN50. When ordering, give the fluid, velocity band, process connection, wetted materials, whether the transmitter is integral or remote, cable entry, output set, power supply and pipe size. Note: the ordering table lists power as 13.5 to 42 V DC (85 to 265 V AC converter optional), while the specification table gives 16 to 32 V DC – confirm the supply against the form ordered.
Dimensions
The catalog gives insertion probe dimensions for the TGF460. Probe length sets how far the sensor reaches into the pipe, and overall length is probe length plus the transmitter head. No bore length table for the wafer or flanged forms is printed for this model, so the figures below are the insertion dimensions, with inches worked out from millimetres at 25.4 mm to the inch.
| Insertion probe length | Overall length | Pipe size |
|---|---|---|
| 255 mm (10.04 in) | 395 mm (15.55 in) | DN25 to DN150 (1 to 6 in) |
| 320 mm (12.60 in) | 460 mm (18.11 in) | DN25 to DN250 (1 to 10 in) |
| 395 mm (15.55 in) | 535 mm (21.06 in) | DN25 to DN400 (1 to 16 in) |
| 500 mm (19.69 in) | 640 mm (25.20 in) | DN25 to DN600 (1 to 24 in) |
Choose the shortest probe that reaches the right depth in the pipe: too short will not sit in the main flow, and far too long is harder to fit and support. Use the pipe size range for each probe in the table above, and set the exact fitting depth from the installation instructions.
Also in this range: the Thermal Flow Meter TGF680, the larger thermal model for gas and steam, up to 240 Nm/s and 450 °C; the Thermal Flow Meter TGF410, the economical thermal model for air and nitrogen, for indoor use; the Thermal Flow Meter TGF260 Micro, the small threaded thermal meter for DN15 to DN25 gas lines; and the vortex range on the flow meter hub page, including the Vortex Flow Meter VFM60 for gas, steam and liquid. Compared with the TGF680, the TGF460 is the lower-cost choice for ordinary gas service up to 150 °C and 180 Nm/s; compared with the TGF410, it covers more gases and larger pipes.
Document
- TGF460 Compressed Air Flow Meter Datasheet (PDF, Comate)
The meter is described in the COMATE 2026-2027 catalog, thermal mass flow meter chapter, pages 34 to 37, where the full measuring range and ordering code tables are printed. This page gives the main figures from that chapter in summary form.