Vortex Flow Meter VFM80 – Gas, Steam and Liquid
The Vortex Flow Meter VFM80 is a vortex meter for gas, steam and liquid, built for high-velocity lines. It covers all three media in one instrument, and shares its accuracy, power, ambient limits, protection and materials with the VFM60. It differs in outputs and velocity range, making it the choice for high-velocity gas and steam duty.

It works on the vortex shedding principle: a bluff body sheds vortices alternately from each side, and the shedding rate rises with flow velocity. The meter counts that rate, with no moving parts in the stream to wear – well suited to steam and gas lines where flow swings widely.
The VFM80 meters gas, steam and liquid – it is not gas-only. Respect the size, velocity, temperature and pressure limits below. For very small gas-only lines, see the micro meters at the end of this page.
Features
- One meter for gas, steam and liquid – not gas-only; a single meter type for all three media.
- Built for high-velocity lines – gas and steam reach up to 120 m/s in expanded form on larger sizes.
- Widest gas and steam velocity range in this range – standard up to 60 or 70 m/s, expanded up to 120 m/s.
- Pulse and 3 x 4-20 mA outputs, with RS485 and Bluetooth.
- Readings shown on the meter display at the line.
- No moving parts in the stream to wear; well suited to steam and gas lines where flow swings widely.
- Shares accuracy, power, ambient limits, protection and materials with the VFM60.
- 16 to 32 V DC power, -20 to 60 °C ambient, IP65/IP67 protection.
Specification
Measurement range
The velocity range is where the VFM80 stands apart. Gas and steam reach up to 120 m/s in expanded form on larger sizes; the standard range is up to 60 or 70 m/s. Liquid covers 0.3 to 6 m/s.
| Size | Gas and steam, standard | Gas and steam, expanded |
|---|---|---|
| DN15 to DN20 | 6 to 60 m/s | 6 to 60 m/s |
| DN25 | 4 to 60 m/s | 4 to 60 m/s |
| DN32 | 4 to 70 m/s | 4 to 80 m/s |
| DN40 to DN300 | 2 to 70 m/s | 2 to 120 m/s |
| Liquid, all sizes | 0.3 to 6 m/s | 0.3 to 6 m/s |
Specification of VFM80 vortex flow meter
| Item | VFM80 detail |
|---|---|
| Process connection | Flange or wafer, DN15 to DN300 |
| Body styles | Wafer and flanged |
| Nominal sizes | DN15 to DN300, both styles |
| Flange standards | DIN PN16, PN25, PN40, PN63; JIS 10K, 20K, 30K; ANSI Class 150, 300, 400 |
| Extended ratings | Mode codes to Class 900 and 150 barg |
| Medium temperature | Standard -40 to 150 °C; medium -40 to 250 °C; high -40 to 350 °C |
| Fluid pressure | Up to 16 Bar wafer; 16, 25, 40 or 63 Bar flanged |
| Flow accuracy | ±1.0% of reading |
| Pressure accuracy | ±0.5% of full scale |
| Temperature accuracy | ±1.0 °C, or ±1% of full scale above 100 °C |
| Outputs | Pulse and 3 x 4-20 mA; RS485 and Bluetooth |
| Power supply | 16 to 32 V DC |
| Ambient temperature | -20 to 60 °C |
| Protection | IP65 and IP67 |
The VFM80 is a natural choice for steam mass flow, where compensated mass measurement is needed. It also fits gas and liquid lines in refineries, petrochemical and chemical plants, and in food and pharmaceutical plants where hygiene matters.
Model selection
| Selection | VFM80 options |
|---|---|
| Body style | Wafer or flanged |
| Nominal size | DN15 to DN300 |
| Flange standard | DIN PN16, PN25, PN40, PN63; JIS 10K, 20K, 30K; ANSI Class 150, 300, 400 |
| Extended rating | Mode codes to Class 900 and 150 barg |
| Fluid temperature | Standard -40 to 150 °C; medium -40 to 250 °C; high -40 to 350 °C |
| Outputs | Pulse and 3 x 4-20 mA; RS485 and Bluetooth |
| Velocity range | Standard up to 60 or 70 m/s (gas and steam); expanded up to 120 m/s; liquid 0.3 to 6 m/s |
Dimensions: DN sizes and face-to-face length L
The VFM80 is made from DN15 to DN300 (1/2 to 12 inches); the face-to-face length L below is for Class 150 and Class 300 flanged models.
| DN size | Size (inches) | L Class 150 (mm) | L Class 150 (inches) | L Class 300 (mm) | L Class 300 (inches) |
|---|---|---|---|---|---|
| DN15 | 1/2 | 186 | 7.32 | 186 | 7.32 |
| DN20 | 3/4 | 186 | 7.32 | 186 | 7.32 |
| DN25 | 1 | 186 | 7.32 | 186 | 7.32 |
| DN32 | 1-1/4 | 186 | 7.32 | 186 | 7.32 |
| DN40 | 1-1/2 | 186 | 7.32 | 206 | 8.11 |
| DN50 | 2 | 186 | 7.32 | 206 | 8.11 |
| DN65 | 2-1/2 | 206 | 8.11 | 226 | 8.90 |
| DN80 | 3 | 206 | 8.11 | 226 | 8.90 |
| DN100 | 4 | 206 | 8.11 | 226 | 8.90 |
| DN125 | 5 | 226 | 8.90 | 256 | 10.08 |
| DN150 | 6 | 226 | 8.90 | 256 | 10.08 |
| DN200 | 8 | 226 | 8.90 | 256 | 10.08 |
| DN250 | 10 | 256 | 10.08 | 306 | 12.05 |
| DN300 | 12 | 306 | 12.05 | 356 | 14.02 |
When choosing between this model and the others in the range, the deciding points are usually the media, the size and the top velocity. The VFM80 covers gas, steam and liquid from DN15 to DN300, with the widest gas and steam velocity range in this range. For the same media in a standard velocity range, see the Vortex Flow Meter VFM60. For small gas-only lines, see the Vortex Flow Meter VFM55MV Micro and the Vortex Flow Meter VFM52MV Micro. The vortex flow meter hub page covers the VFM60MV flanged 150C model in detail.
Document
- VFM60 Series Datasheet (PDF, Comate) – the series datasheet for the VFM60 platform the VFM80 shares
If you are unsure which size, temperature version or velocity range fits your line, check the figures above first.