Eaton Overcurrent Protection Device: this page lists the 27 genuine Eaton parts that KBS Industries carries for Eaton overcurrent protection devices in fire pump controllers, shown with their Eaton part numbers below.

These Eaton Overcurrent Protection Device parts are the circuit breakers that protect fire pump controller circuits against overload and short circuit. They are listed by size — Size 2, Size 3, Size 5 and Size 6 — and by amp rating, from 15 amps up to 1,600 amps, so you can match the breaker to the circuit it protects.

Use the Eaton part number below to match the component before you order: some amp ratings appear in more than one size, and breakers from different sizes are not interchangeable. For the full Eaton fire pump range, start from our Eaton Fire Pump Control Spares hub page. For the jockey ranges, see Eaton XTJL Components, Eaton Jockey Touch XTJP/XTJY Components, Eaton XTJP/XTJY Components, Eaton FDJP/FDJY Components, Eaton FD120 Components and Eaton FD140 Components, and for the electric ranges, see Eaton Electric Common Components, Eaton A200 Series Components, Eaton Freedom Series Components, Eaton XT Series Components, Eaton Transfer Switch Components, Eaton LMR Plus Components, Eaton EPCT Fire Components and Eaton EPCT Fire Transfer Switch Components.

Size 2

DescriptionEaton part no.DescriptionEaton part no.
15PDG23P0015TFFN20PDG23P0020TFFN
25PDG23P0025TFFN35PDG23P0035TFFN
40PDG23P0040TFFN50PDG23P0050TFFN
70PDG23P0070TFFN80PDG23P0080TFFN
90PDG23P0090TFFN100PDG23P0100TFFN
110PDG23P0110TFFN125PDG23P0125TFFN
150PDG23P0150TFFN175PDG23P0175TFFN
200PDG23P0200TFFN225PDG23P0225TFFN

Size 3

DescriptionEaton part no.DescriptionEaton part no.
175PDG33P0175TFAN200PDG33P0200TFAN
225PDG33P0225TFAN250PDG33P0250TFAN
300PDG33P0300TFAN350PDG33P0350TFAN
400PDG33P0400TFAN500PDG33P0500TFAN
600PDG33P0600TFAN

Size 5

DescriptionEaton part no.DescriptionEaton part no.
1200PDG53P1200E2NN

Size 6

DescriptionEaton part no.DescriptionEaton part no.
1600PDG63P1600E2NN

What Are Eaton Overcurrent Protection Device?

An Eaton Overcurrent Protection Device is a circuit breaker that guards a fire pump controller’s circuits against overload and short circuit. When the current through a circuit rises above the breaker’s rating, the breaker trips and opens the circuit, stopping the fault before it can damage the controller, the wiring or the pump motor. The breakers on this page are Eaton PDG frame breakers, listed by frame size and amp rating so the right breaker can be matched to each circuit.

In these installations, the breaker sits in the controller’s power path, protecting the circuits downstream of it. The Size 2 breakers cover the smaller circuits, from 15 amps to 225 amps, while the Size 3 breakers cover 175 amps to 600 amps. The Size 5 and Size 6 breakers protect the largest circuits, at 1,200 amps and 1,600 amps, for the biggest fire pump installations.

The amp ratings on this page overlap between sizes: for example, 175 amps, 200 amps and 225 amps appear in both Size 2 and Size 3. The size matters as much as the rating, because the breakers have different frames, dimensions and mounting. When ordering Eaton Overcurrent Protection Device parts, match both the amp rating and the frame size to the breaker in your controller.

Every one of these Eaton Overcurrent Protection Device parts is a genuine Eaton part, supplied with its Eaton part number. Genuine parts keep the controller’s ratings, connections and behaviour exactly as Eaton designed them, which matters in a fire pump application where the protection must operate correctly when it is needed. For more background on Eaton’s fire pump range, see Eaton’s fire pump page.

How to Choose Eaton Overcurrent Protection Device

Match the part to your controller before you order. The checks below cover the most common mistakes when ordering Eaton Overcurrent Protection Device spares.

  • When ordering Eaton Overcurrent Protection Device parts, check the Eaton part number on the failed breaker or on your controller’s parts list — similar amp ratings in different sizes are not interchangeable.
  • Match the frame size first: Size 2, Size 3, Size 5 and Size 6 breakers have different frames and mountings.
  • Match the amp rating within the size: the Size 2 range runs from 15 amps to 225 amps, and the Size 3 range from 175 amps to 600 amps.
  • Check the rating carefully: 175, 200 and 225 amps appear in both Size 2 and Size 3, so the part number is the only sure check.
  • For the largest circuits, the Size 5 breaker is 1,200 amps (PDG53P1200E2NN) and the Size 6 breaker is 1,600 amps (PDG63P1600E2NN).
  • If the breaker has tripped, find and fix the cause of the overload or short circuit before fitting the replacement.
  • If you are unsure which part fits your controller, email sales@kbsindustries.com with the controller model and the part number you need.

Order Eaton Overcurrent Protection Device from KBS Industries

Order your Eaton Overcurrent Protection Device parts from KBS Industries by emailing sales@kbsindustries.com with the Eaton part numbers you need and the quantity for each. We will confirm availability and pricing, and arrange delivery to your site. If a part you need is not listed here, tell us the number — we can often source other Eaton fire pump spares on request.

These overcurrent protection parts sit alongside spares for the other Eaton fire pump controller ranges carried by KBS Industries. See our Eaton Fire Pump Control Spares hub page for the full list, and the neighbouring sections — Eaton XTJL Components, Eaton Jockey Touch XTJP/XTJY Components, Eaton XTJP/XTJY Components, Eaton FDJP/FDJY Components, Eaton FD140 Components, Eaton FD120 Components, Eaton EPCT Fire Transfer Switch Components, Eaton EPCT Fire Components, Eaton LMR Plus Components, Eaton XT Series Components, Eaton Transfer Switch Components, Eaton Freedom Series Components and Eaton A200 Series Components — for parts from the other controller families.

When you order, quote the full Eaton part number from the tables above. The part number identifies both the frame size and the amp rating: the Size 2 breakers carry PDG23 part numbers, the Size 3 breakers carry PDG33 part numbers, the Size 5 breaker carries a PDG53 part number and the Size 6 breaker carries a PDG63 part number. Within each size, the amp rating is part of the number too — PDG23P0150TFFN is the 150-amp Size 2 breaker and PDG33P0600TFAN is the 600-amp Size 3 breaker. Matching the full part number is the surest way to order the right breaker for your controller.